KL08RF + SQ610RF + CO10RF First time setup

KL08RF + SQ610RF + CO10RF First time setup


Connect KL08RF + SQ610RF + CO10RF – First time setup

Step 1: Turn on the devices

1.1. Plug in the CO10RF coordinator.

1.2. Power up the KL08RF via mains.

1.3. Make sure SQ610RF is charged and is ON - hold Tick to turn on.

Step 2: Check Lights

2.1. On KL08RF – “Network Status” LED should be blinking.

2.2. On CO10RF – LED should be ON and solid red.

2.3. SQ610RF should have Language selection.

Step 3: Start pairing and assign

3.1. On CO10RF hold the button for 5 seconds, ring light starts blinking red (pairing mode).

3.2. On KL08RF on start-up the “Network Status” light should blink once every second - pairing mode. If the light is blinking twice with a pause, press the “Reset” button to put it in pairing mode (blinking once a second).

On a successful pair the KL08RF “Network Status” light will go solid green.

3.3. On SQ610RF select your language, “CONNECT WITH NETWORK” will appear, wait till it pairs to the CO10RF.

On successful pair “SYSTEM TYPE UNDERFLOOR” will appear.


3.4. Assign SQ610RF to a KL08RF zone:

“SYSTEM TYPE UNDERFLOOR” accept with Tick,

“SELECT THE CONTROL BOX” – select the default “1”, accept with Tick,

3.4.1. If an error message says control box 1 is not available, press the Pair button once – a zone will light up temporarily indicating this WC control box number, then select that number.

“SELECT THE ZONE NUMBER” – use Up/Down to select a zone to assign, accept with Tick,

“ADDITIONAL ZONE” – leave it at “- -" and press Tick to finish or if needed, chose a second zone using Up/Down arrows and accept with tick.

Step 4. Finish and test

4.1. On CO10RF press and hold the button for 5 seconds till the ring light goes solid (stopping pairing, closing network).

4.2. On SQ610RF increase set temperature above room temperature to get a call for heat and check if KL08RF assigned zone light comes on.


Resetting

In case of not pairing or wrong assigned zone you can always start new by clearing any connected device by factory resetting:

On CO10RF hold the button for 15 seconds till the ring light goes orange, this will remove any connected device on the CO10RF and their assignments.


Important:

Do not use CO10RF and UGE600 at the same time
After pairing, you can add more thermostats or actuators

    • Related Articles

    • KL08RF - Manual and Spec Sheet

                           The KL08RF has 8 control zones, each with connections for up to 3 heating zones (actuators). The pump logic and boilers logic, a connection for Dew point sensor and the C/O input for automatic switching from heating to cooling ...
    • KL08RF - Wiring Diagram

      KL08RF : Wiring Diagram (1.1.1) . __________________________