Question: Why when I am increasing the temp on my RT310, but the heating is not increasing?

Answer: Check you have not set the thermostat in Frost protection mode – snowflake on screen.
If you can increase the set temperature cut boiler does not come on, check the wiring from the thermostat to the boiler or the boiler itself.




Question: Can I use the RT310 on a vokera boiler or is it for certain boilers only?

Answer: The RT310 is a hard-wired unit that has a volt free COM and NO port. Meaning the unit can switch 0-230V devices, just make sure the boiler does not exceed the RT310 max 3(1)A switching current.




Question: What power supply adapter is used for the RT310i gateway?

Answer: The iTG310 and iTG500 gateways use same power adapter rated at 5DC V, pin size 10mm long/deep, 3.46 mm outer (negative), 1.3mm inner (positive). A universal multi head power adapter usually has this size, however make sure it is rated at 5DC V.




Question: When requesting a STA or SRT removal via the form what is the expect removal time, how quick will it be done?

Answer: You will get a notification in the email when it has been removed. Typically, you should allow for up to 2 working days for the form to be processed.



Question: RT310 / RT310TX / RT310RF – How long does it take for the boiler to fire when the thermostat has called for heating?

Answer: The hard-wired RT310 should trigger the boiler in under 3 seconds from the start of the call.
The RT310TX / RT310RF can take up to 10 seconds before the receiver receives the call signal and switches, triggering the boiler.
You can also test the pairing using the Test/Pairing button: single-press it to put the thermostat in test mode (“TE9” on screen). While “TE9” is on screen, any successfully paired receiver will respond by flashing its LED lights.
Note: some boilers have a built-in start-up delay to avoid short on/off cycles and reduce wear, which can affect the boiler start-up response time.