RT510 - Programs Schedules Explained

RT510 - Programs Schedules Explained

 RT510 Series : Program Schedules Explained (4.1.1.


Description :      Program schedules allow you to specify which times of the day you want your heating to come on and to what temperature you would like it to maintain your house. The RT510 Series Thermostat comes with some pre-set default program schedules which you can use as is, or easily change to meet your personal requirements.


Types of Schedules :   


The RT510 Series has two different modes in which you can program schedules. The programming mode can be set in the Installer Mode function for your thermostat, please see the article RT510RF Installer Mode - Programming Mode Selection (salus-tech.com)


5/2 :                        The first option defines two sets of program schedules. One set of times and temperatures will be used for the week period (Monday to Friday) and another separate set that will be used only at the Weekend, hence 5 / 2. 


Individual :              The second option lets you define a program schedule for each day of the week individually, so you can have your heating come on at different times and at different temperatures every day. This is known as ‘individual’ and displayed as ‘7d’ in the installer mode selection.



The Schedules :      Each program schedule contains 6 start times and 6 set points to define your required temperature. It is necessary when programming a schedule to complete all 6 set points.


The start times must be set sequentially, so each must be set at a later time than the one before. ie. program 2 must have a later start time than program 1. Failure to do so causes conflicts and will prevent your thermostat from following the schedule making it appear to not be working correctly.


                                Temperature setpoints are set for each of the program start times.



Operation :             Your RT510 Series Thermostat works in a manner where the program schedules maintain a series of temperatures that you set throughout the day, unlike the old central heating programmers that had defined On and Off times.


                                Therefore, when you set a temperature setpoint your heating will turn on to reach the setpoint and then periodically turn on and off to maintain that temperature until the next defined setpoint temperature.


                                For example, if your first setpoint of the day is at 22’C and your second at say 11am is set to 20’C then at 11am your heating will allow your room to cool down from 22’C to 20’C. If your room falls below 20’C then your heating will turn back on to enable the room to be kept at that temperature even if the third setpoint is not until 5pm when you want your heating to come back up to say 22’C. So even though your second setpoint is the lowest, it is not an ‘Off’ time and your heating will keep turning on and off to maintain the minimum temperature of 20’C that you set.


Examples :              Below are some examples of program schedules with an explanation of how they operate.


    


Start Time

Setpoint Temperature

06.00am

20̊


08.00am

14̊


12.30pm

20̊


01.30pm

14̊


05.30pm

22̊


11.00pm

10̊




This example may be used by a household who are out at work during the day.


06:00am    The heating comes on and warms the house to 

                    20 ̊c for waking up and getting ready for work.


08:00am   Having left for work, the house is now allowed   to cool to a temperature of no lower than   14 ̊c to save energy.


12:30pm   The temperature is increased to 20 ̊c so the  house is not cold when returning home from work. for lunch.


01:30pm   Again, as the house is empty the temperature is lowered to save energy.


05:30pm  Everyone is now on their way home from work, so the house is made warm and comfortable for their arrival.


11:00pm  The house is now allowed to cool for a comfortable night’s sleep.




Start Time

Setpoint Temperature

08.00am

21

11.00am

21

02.00pm

21

05.00pm

21

08.00pm

21

10.00pm

10



This example may be used at a weekend when the household occupants are in the house during the day, and they simply want the heating on at a constant temperature until the end of the day.


08:00am   The heating comes on and warms the house to a comfortable temperature of 21 ̊c .


11:00am   The heating is still set to maintain the temperature of 21 ̊c to keep the house comfortable throughout the day.


02:00pm   As a constant temperature is required                          the 05:00pm  setpoints are all set to the                      same value until the 08:00pm last setting                    of the day.


10:00pm  A lower temperature is now set to turn the heating off and allow the house to cool down overnight to no lower than 10 ̊c.




Below is an example of a common mistake made in the program schedules which makes it appear that the thermostat is not working and is randomly turning the heating On and Off.




Start Time

Setpoint Temperature

06.00am

22

08.00am

20

12.30pm

22

01.30pm

20

06.00pm

22

11.00pm

14



In this example the common mistake made is that the user is trying to emulate the ON and OFF times of an older programmer but has not set the ‘OFF’ times to a low enough temperature.


They therefore think that the heating will turn On at 06:00am until 08:00am at which point it will switch Off until the next setpoint at 12:30pm. Then again, they think the heating will be ‘On’ until 13:30pm when it is switched ‘Off’ until 06:00pm and so on.


They are then surprised when the heating is turning On and Off randomly all through the day. In actual fact the thermostat will not let the room fall below 20’C and so will keep turning on the heating to maintain that temperature.


If you want the heating to turn off for a period of time you need to set the effective ‘Off’ temperature to be well below the normal room temperature for example 14’C as shown in the last setting for the night.





                                            ____________________________
    • Related Articles

    • RT510 Series - Setting Programs Schedules

      ​  RT510 Series : Setting Program Schedules (4.4.1) . Description :      Program schedules allow you to specify which times of the day you want your heating to come on and to what temperature you would like it to maintain your house. The RT510 Series ...
    • RT510RF - Default Program Schedules

       RT510RF : Default Program Schedules  (4.3.1) . Description :      The RT510 Series Thermostat comes with some pre-set program schedules for you to use. These are in the format of 5 / 2  meaning a set of program times for weekdays and a separate set ...
    • RT510 Series Thermostat Videos

      Pairing. Follow this procedure if you have a red flashing light on your Receiver. ​ ​ Receiver Controls ( Auto/Manual Mode, LED's Explained) Common Issues and Frequently Asked Questions General Use : Turning your Heating On Blank Screen - No Display ...
    • RT510+ Series : Manuals

    • RT510RF - Programming Mode Selection (Installer Mode)

       RT510RF : Installer Mode – Programming Mode Selection (5.13.1) . Description :      Installer Mode takes you into the device installation settings which on the RT510 Series allows you to change the settings in the table below. Setting No. Function ...